It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.
Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything.
Load banks help highlight a large range of faults on the equipment it tests. The first objective when testing with an electric bank is to ensure your equipment’s power supply is reliable. The underlying question that needs answering is whether your equipment will have sufficient power supply to ensure uninterrupted operational performance. The load bank also tests that the equipment is not faulty, that there are no faults in construction, that the aging of the equipment is in line with expectations, that the components are reliable and that there are no pending breakdowns or early signs of wear and tear. The load bank also ensures that the product delivers power conform to its specification.
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
JUNXY series AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively, which includes (click to view more):
Technical Specifications | |
---|---|
Model | JUNXY-AC480V-138KW-RLC AC Load Bank |
Load Element | Resistor, inductor and capacitor |
Load Voltage | Rated load voltage: AC480V 3P4W & AC277V 1P2W |
Frequency | 50Hz/60Hz |
3Phase Load Power | R=138KW @AC480V 3P4W 50/60Hz L=138KVar @AC480V 3P4W 60Hz C=138KVar @AC480V 3P4W 50Hz |
3Phase Load Power | R=178.4KW, @AC545.6V 3P4W 50/60Hz L=178.4KVar @AC545.6V 3P4W 60Hz C=178.4KVar @AC545.6V 3P4W 50Hz |
Load Steps @AC277V 1P2W | Resistive load, phase A/B/C same load steps(W): 5.6, 11.2, 22.4, 44.8, 89.8, 179.6, 359.4, 718.8, 1437.6, 2875.2, 5750.6, 11501.4, 23002.8 Inductive load, phase A/B/C same load steps(Var): 5.6, 11.2, 22.4, 44.8, 89.8, 179.6, 359.4, 718.8, 1437.6, 2875.2, 5750.6, 11501.4, 23002.8 Capacitive load, phase A/B/C same load steps(Var): 5.6, 11.2, 22.4, 44.8, 89.8, 179.6, 359.4, 718.8, 1437.6, 2875.2, 5750.6, 11501.4, 23002.8 |
Control Mode | 1. Local control panel by push buttons 2. Remote control by PC software |
Cooling Mode | Force-air vertical cooling. |
Dimension & Weight | Resistive/capacitive bank: 1100*1370*1408mm--482KG Inductive bank: 1100*1370*1408mm--920KG |
Mobility | Four wheels |