AC120V & AC240V 20KW Split Phase RLC Load Bank Test System

×

A split phase RLC load bank is a type of load bank that can simulate different types of loads by using resistors, inductors and capacitors in series. It can create pure resistive, pure inductive, pure capacitive or combined loads with leading or lagging power factor https://www.junxypowersolutions.com/resistive-capacitive-inductive-ac-load-bank. A split phase RLC load bank can also output two voltages that are 180 degrees out of phase with each other by using a center-tapped transformer. This allows it to test single-phase or three-phase power sources with different voltages, currents, power factors and harmonics. A split phase RLC load bank can also be used for inverter anti-islanding test, which is a safety feature that prevents an inverter from feeding power to the grid when the grid is down. https://www.junxypowersolutions.com/resistive-capacitive-inductive-ac-load-bank

The load bank is designed for the AC120V & AC240V 2phase 3wires split phase inverter load test. Include the pure resistive, pure inductive and pure capacitive loading or combination loading. Power factor adjustable. 2 control modes: local panel by push buttons & PC software remote control.

AC120V240V-20KW-RLC-AC-LOAD-BANK-JUNXY-副本-scaled.jpg
Technical Specifications
ModelJUNXY-AC120V&240V-20KW-RLC Split Phase AC Load Bank
Load ElementStainless steel resistor, inductor & capacitor
Load Voltage
Split-Phase: AC240V 2phase 3wires(L1/N/L2)

AC120V(L1-N), AC120V(L2-N), AC240V(L1-L2)

NOTE: Over voltage loading is PROHIBITED
Load Frequency60Hz
Total Load PowerR=20.2KW @AC240V 2P3W, (10.1KVar per phase),

L=20.2KVar @AC240V 2P3W, (10.1KVar per phase),

C=20.2KVar @AC240V 2P3W, (10.1KVar per phase)
Resistive

Load Steps
L1-N@AC120V:

0.01KW, 0.02KW*2, 0.05KW, 0.1KW, 0.2KW*2, 0.5KW, 1KW, 2KW*2, 4KW (10W-10.1KW adjustable)

L2-N@AC120V:

0.01KW, 0.02KW*2, 0.05KW, 0.1KW, 0.2KW*2, 0.5KW, 1KW, 2KW*2, 4KW (10W-10.1KW adjustable)

L1-L2@AC240V:

0.02KW, 0.04KW*2, 0.1KW, 0.2KW, 0.4KW*2, 1KW, 2KW, 4KW*2, 8KW (20W-20.2KW adjustable)
Inductive

Load Steps
L1-N@AC120V:

0.01KVar, 0.02KVar*2, 0.05KVar, 0.1KVar, 0.2KVar*2, 0.5KVar, 1KVar, 2KVar*2, 4KVar (10Var-10.1KVar adjustable)

L2-N@AC120V:

0.01KVar, 0.02KVar*2, 0.05KVar, 0.1KVar, 0.2KVar*2, 0.5KVar, 1KVar, 2KVar*2, 4KVar (10Var-10.1KVar adjustable)

L1-L2@AC240V:

0.02KVar, 0.04KVar*2, 0.1KVar, 0.2KVar, 0.4KVar*2, 1KVar, 2KVar, 4KVar*2, 8KVar (20Var-20.2KVar adjustable)
Capacitive

Load Steps
L1-N@AC120V:

0.01KVar, 0.02KVar*2, 0.05KVar, 0.1KVar, 0.2KVar*2, 0.5KVar, 1KVar, 2KVar*2, 4KVar (10Var-10.1KVar adjustable)

L2-N@AC120V:

0.01KVar, 0.02KVar*2, 0.05KVar, 0.1KVar, 0.2KVar*2, 0.5KVar, 1KVar, 2KVar*2, 4KVar (10Var-10.1KVar adjustable)

L1-L2@AC240V:

0.02KVar, 0.04KVar*2, 0.1KVar, 0.2KVar, 0.4KVar*2, 1KVar, 2KVar, 4KVar*2, 8KVar (20Var-20.2KVar adjustable)
Power FactorLeading and lagging power factor 0-1.0 adjustable
Load AccuracyR/C: ±5%, L: ±10%,
Digital MeterVoltage, Current, Power, Frequency, Power Factor and etc.
Power SupplyAC120V 60Hz, single phase
Control Mode1. Manual control by push button

2. Remote control by PC software
Wire ConnectionsCopper bus bar for wire connections
Insulation ClassF
Protection LevelIP20(indoor use)
Fan Noise75dB
Cooling ModeForce-air vertical cooling
Work ModeContinuous work