JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in harsh, dusty or corrosive environment working in good condition, when you need them most, if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.
The AC/DC load bank loading test preventative maintenance of such power supply systems could free you from power supply failure, to ensure constant uptime for your power systems and make you prepared for anything. Downtime could also be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.
Load bank testing could help highlight a large range of faults on the power supply systems it test. The first goal achieved when testing with JUNXY AC/DC load bank is to ensure your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications. The underlying question that JUNXY series AC/DC load bank could answer you is--“how is my power supply systems constant uptime(technical performance) ?” The load bank also tests that the power supply system is not faulty, no faults in construction and components reliable, that the aging of the power supply system is in line with expectations and that there are no pending breakdowns or early signs of wear and tear.
JUNXY offers you whole AC/DC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC/DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
JUNXY
AC/DC load banks applications
|
JUNXY
series load banks loading elements (load bank types)
Alloy resistors, inductors capacitors loading elements are combined used in JUNXY series AC/DC load bank as per clients’ need in different applications:
|
Practice using the load bank before actual loading test, so as to be familiar with load bank control. Note: please read the designed diagram and manual before any operation.
Technical Specifications | |
Model | JUNXY-AC120V&AC250V-23A-R AC Load Bank |
Load Element | Resistors |
Load Voltage | 1. AC120V 1P2W, 50/60Hz 2. |
Rated Current | 23A per channel: 23A@AC120V, 23A@AC250V |
Load Channels | 5 independent load channel |
Load Steps
Per Channel |
Each channel has same load steps as below:
0.1A, 0.2A, 0.2A, 0.5A, 1A, 2A, 3A, 6A, 10A 23A@AC120V, |
Power Factor | 1.0 |
Load Accuracy | Resistor: ±5% |
Mains Voltage | 240V 50Hz, single phase |
Control Modes | Local control panel: by breakers and push buttons |
Power Source Input | Terminal block: L & N |
Load Output | Terminal block: 5 independent channel output L1 & N1, L2 |
Insulation Class |
F |
Fan Noise | 75dB |
Cooling Mode | Force-air vertical cooling, by axial-flow fans. |
Work Mode | Continuous work |
Alarm | Over heating buzzer alarm |
Dimension | 600*850*1268mm |
Weight | Around 100kg |