JUNXY 230V 3KW Immersion Cooling Load Banks Server Emulator

×

Data center immersion cooling is a technique that helps improve thermal design by directly immersing IT hardware in a non-conductive liquid. The heat generated by the electronic components is directly and efficiently transferred to the fluid, thereby reducing otherwise needed active cooling components, such as interface materials, heat sinks and fans. Immersion cooling can also help reduce electricity consumption, water usage, carbon footprint and real estate costs for data centers. There are two main types of immersion cooling: Single-phase immersion cooling uses a liquid that remains in its liquid state throughout the cooling process, while two-phase immersion cooling uses a liquid that boils and vaporizes when it contacts the hot components, then condenses back to liquid when it cools down.

An immersion load bank is a type of load bank that uses water-immersion elements to dissipate heat generated by the electrical load. A load bank is a device that simulates an electrical load and tests the performance of power sources such as generators, batteries, or UPS systems. An immersion load bank can be water-cooled or air-cooled, depending on the cooling medium used to remove heat from the water-immersion elements。Immersion load banks are typically used for indoor applications where noise and space are restricted, or for marine applications where seawater can be used as a coolant.

The JUNXY rack mounted AC & DC load banks are designed especially for internet data center (IDC) test and commissioning. Load bank integrated system test (IST) could precisely simulate the data center’s electricity consumption, heat dissipation, air flow, hot & cold aisle testing, thus to ensure the effective operation of power supply & distribution system (generator, UPS, EPS included), air conditioning system, lightning protection and earthing system, monitoring system, data center integrated environments, cabinet IT environment, providing independent verification of integrated system testing. Successful IST(integrated system test) should have installation of server load banks in data center and server room etc, JUNXY provides resistive, reactive and capacitive load banks in low or medium voltage to cover the entire scope of your commission and testing requirements.

Applications:
  • Data center & server room cooling system test
  • Data center air flow, hot/cold aisle environment inspection
  • Validating the tire level of data center
  • Validating the reliability of data center power supply & distribution system
  • Testing the main network before connecting user devices (servers, switches, etc.)

The load bank is suitable for the data center those use immersion cooling for the server. JUNXY immersion cooling load bank is suitable & reliable for the immersion data center loading test, simulation exactly perfect for the data center immersion.

Technical Specifications
ModelJUNXY-AC230V-3KW-R Resistive AC Load Bank
Load ElementStainless steel resistor
Load VoltageAC230V 1P2W, 50/60Hz
Rated Power3KW @AC230V 1P2W, 50/60Hz
Rated Current13A @AC230V 1P2W, 50/60Hz
Load Steps
Total 3 load steps: 1KW*3

Load steps with light indicator
ProtectionOver heat 85-90 degree C preset thermal protection
Power FactorPF=1
Load Accuracy±5%
Control ModeManual control by mini switches with light indicator
Insulation ClassF
Protection LevelIP20(indoor use)
Cooling ModeImmersion cooling by client’s non-conducted coolant

Natural cooling is prohibited
Work ModeContinuous work
Ambient Temperature-10℃~+50℃
Load Input Cables1 C19-C20 cable(provided by client)
Dimension1U 19 inch rack, depth 800mm
Weight9.7KG
MobilityTwo front handles
Work Humidity≤95%
Work Altitude≤2500 meters

NOTE: Each load bank includes the standard items:

  1. One Load Bank Main Unit.
  2. 1 C19-C20 cable(optional)