24V&48V Dual Voltage 26KW DC Load Bank

×

Why load bank testing is important?

JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in harsh, dusty or corrosive environment working in good condition, when you need them most, if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.

The AC/DC load bank loading test preventative maintenance of such power supply systems could free you from power supply failure, to ensure constant uptime for your power systems and make you prepared for anything. Downtime could also be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.

Load bank testing could help highlight a large range of faults on the power supply systems it test. The first goal achieved when testing with JUNXY AC/DC load bank is to ensure your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications. The underlying question that JUNXY series AC/DC load bank could answer you is--“how is my power supply systems constant uptime(technical performance) ?” The load bank also tests that the power supply system is not faulty, no faults in construction and components reliable, that the aging of the power supply system is in line with expectations and that there are no pending breakdowns or early signs of wear and tear.

JUNXY offers you whole AC/DC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output

Technical Specifications
ModelJUNXY-DC24V&48V-26KW-R Resistive DC Load Bank
Load ElementStainless steel resistors.
Rated VoltageDC48V & DC24V
Rated Power
26KW@DC48V(0.1KW-26KW adjustable),

26KW@DC24V(0.1KW-26KW adjustable)
Load Steps0.1KW, 0.2KW*2, 0.5KW, 1KW, 2KW*2, 5KW*2, 10KW

(0.1KW-26KW adjustable)
Load Accuracy±5%
Digital MeterTesting voltage, current, power, energy
Power Supply220V 50Hz, single phase
Control ModeManual control by push buttons
Wire Connections“+” & ”-” bus bar for load cables connection
Insulation ClassF
Protection LevelIP20(indoor use)
Fan Noise75dB
Cooling ModeForce-air cooling
Work ModeContinuous work
ProtectionsOverheating/Buzzer alarm, Overheating/voltage protection, emergency stop button
Dimension-Weight600*700*900mm-90kg
Ambient Temperature-10℃~+50℃
MobilityFour wheels & lifting lugs
Humidity≤95%
Altitude≤2500 meters

Pls kindly click HERE to review the 24V&48V 26KW load bank operation video from YOUTUBE!