Uninterruptible Power Supply UPS Diode Rectifier with Capacitive RCD AC Load Bank(RCD)

×

JUNXY-AC120V-50KVA-RCD Split Phase Non Linear AC Load Bank

Read More

JUNXY-AC220V-30KW-RCD Non Linear AC Load Bank

Read More

JUNXY-AC220V-6.5KW-RCD AC Load Bank

Read More

JUNXY-AC380V-60KW-RCD Non-linear AC Load Bank

Read More

JUNXY-AC480V-30KW-RCD AC Load Bank

Read More

JUNXY-AC600V-25KW-RCD AC Load Bank

Read More

UPS Diode Rectifier with Capacitive RCD AC Load Bank

JUNXY RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD AC load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test. Below diagram on how JUNXY RCD AC load banks work:

Pls click HERE to download JUNXY ENERGY load bank catalogue for more details, OR could email SALES@JUNXYENERGY.COM for more consultance.

JUNXY resistive & capacitive AC load banks-RCD
Models AC240V-10kW-RCD AC415V-30kW-RCD AC415V-60kW-RCD AC415V-100kW-RCD AC415V-250kW-RCD AC415V-400kW-RCD
Rated Capacity Resistive: 10kW
Capacitive: 10kVAR
Resistive: 30kW
Capacitive: 30kVAR
Resistive: 60kW
Capacitive: 60kVAR
Resistive: 100kW
Inductive: 100kVAR
Resistive: 250kW
Inductive: 250kVAR
Resistive: 400kW
Inductive: 400kVA
Customized solutions could be available upon request.
Rated Voltage 1P: AC240V 3P AC415V, or units can be designated by customer
Customized solutions could be available upon request.
Maximum current 96A 1P: 96A
3P: 288A
1P: 192A
3P: 576A
1P: 319A
3P: 957A
1P: 798A
3P: 2394A
1P: 1278A
3P: 3834A
Frequency 50/60 Hz
PF PF=0.6-1.0
Minimum Load Step 100W, 100VAR 100W, 100VAR 100W, 100VAR 1kW, 1kVAR 1kW, 1kVAR 1kW, 1kVAR
Customized solutions could be available upon request.
Digital Meter Voltage, Current, Frequency, Power and PF displayed by digital meter
Protection Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button.
All protections can be configured optionally
Control Mode Manual control by MCBs or push buttons
Air Flow Horizontal, Force-air cooling
Dimension 51*63*120(cm) 51*97*120(cm) 80*140*185(cm) 80*140*185(cm) 80*150*155(cm) 80*150*190(cm)