Programmable Resistive AC Load Bank®

Programmable Resistive AC Load Bank®


Resistive AC Load Bank

Why need load bank testing? Once your standby power supply systems say UPS (uninterrupted power supply), 
Resistive Load Bank, AC Dummy Load Bank, battery bank, generator, transformers, inverter etc are switched to be loaded when the main power supply in maintenance procedure or stop abnormally, it is really critical to ensure that they MUST be working in good condition when you need them most, especially for those located in harsh, dusty or corrosive environment.

Such stand by & inactive power supply systems could fail without proper preventative maintenance. JUNXY provides a whole range of custom preventative maintenance products solutions to ENSURE constant uptime for your power systems and make you prepared for anything. Downtime could also be reduced by regular preventative maintenance and thorough inspections which are the key to power supply systems maintenance.

What could be achieved by JUNXY programmable AC load banks? JUNXY Resistive Load Bank could help highlight the potential hidden faults of the power supply systems before they could cause a power disruption. be the FIRST goal achieved when testing with JUNXY Resistive Load Bank & AC Dummy Load Bank is to ensure if your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications, which is the MOST IMPORTANT question that JUNXY series programmable AC load bank could answer you. A wide range of conditions that could threaten a power system could be detected by JUNXY load banks say defective equipment, design errors, flawed construction, emissions, natural aging, improper settings on system control components and the negative effects of underutilization.

What products solutions does JUNXY provide? JUNXY series AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications. Our solutions include (click to view more): (1) Pure Resistive AC Load Bank (R) & (2) Rack Mounted AC/DC Load Bank

How is JUNXY load banks resistor? A highly reliable and durable new alloy resistor is used for the JUNXY’s Resistive & Dummy load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with an insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.

What are the JUNXY load bank control modes? Two control modes are available for JUNXY AC load banks: The local panel control mode by push buttons, mini circuit breakers and etc, and the remote control mode by PLC through PC software. Local control mode will be locked once the load bank is switched to remote control mode. By applying the PLC, we could make the load bank an intelligent test system, the load power curve could be preset through PC software, and all electrical parameters of EUT(equipment under test) including current, voltage, apparent power, active power, reactive power, power factor, frequency, and warning info could be achieved automatically by the PC software and displayed by load bank digital meter. Up to 15 load banks at most could be parallel controlled by PC software which generates the test tables, curves, and standard test report.

Pls click HERE to download JUNXY ENERGY load bank catalogue for more details, OR could email SALES@JUNXYENERGY.COM for more consultance.

Show:
Sort By:

3Phase High Frequency UPS Load Bank Test | AC380V/400V/415 135KW Resistive AC Load Bank

Why need load bank testing ? Once your standby power supply systems say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc are switched to be loaded when the main power supply in maintenance procedure or stop abnormally,&..

More

$0.00

3Phase High Frequency UPS Load Bank Test | AC380V/400V/415 25KW Resistive AC Load Bank

Why need load bank testing ? Once your standby power supply systems say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc are switched to be loaded when the main power supply in maintenance procedure or stop abnormally,&..

More

$0.00

AC110V & AC220V 50KW 2Phase 3Wires Split Phase Resistive AC Load Bank

A split phase load bank is a device that can simulate different electrical loads for testing purposes. It can be used to test inverters, generators, transformers and other power sources. A split phase load bank has two output terminals that are out of phase by 180 degrees wi..

More

$0.00

Dual Load Voltage AC240V & AC480V 100KW Resistive AC Load Bank

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inver..

More

$0.00

Dual Load Voltage AC400V & AC480V 600KW Resistive AC Load Bank

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inver..

More

$0.00

JUNXY 380V 550KW Portable Intelligent AC Load Bank Test Generator

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inver..

More

$0.00

JUNXY AC220V 12KW EV Charger Load Bank Simulation Test

Why load bank testing is important?JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in..

More

$0.00

JUNXY AC380V 600KW Resistive AC Load Bank For Standby Generator Commissioning Load Test

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inverter,..

More

$0.00

JUNXY AC400V 500KW Resistive AC Load Bank For Modular UPS Commissioning Load Test

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inverter,..

More

$0.00

JUNXY AC415V 600KW Programmable Resistive AC Load Bank

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inverter,..

More

$0.00

JUNXY ENERGY AC240V 500KW Resistive AC Load Bank

What is the pure resistive AC & DC load bank?Load bank applications:JUNXY series pure resistive load bank is a safe and simple way to provide loading test, commissioning test, aging test, acceptance test for UPS, generator, AC voltage regulator, transformer, PV inverter,..

More

$0.00

JUNXY ENERGY AC415 400KW Resistive AC Load Bank

What is the pure resistive AC & DC load bank?Load bank applications:An AC load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. During testing, adjustme..

More

$0.00

JUNXY-240V/415V-40A-R Resistive AC Load Bank

Why load bank testing is important?JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in..

More

$0.00

JUNXY-300V/520V-40A-R Resistive AC Load Bank

Why load bank testing is important?JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located..

More

$0.00

JUNXY-AC120V&AC250V-23A-R Resistive AC Load Bank

Why load bank testing is important?JUNXY series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located..

More

$0.00